Overview:

1. The corrosion of protected and unprotected metal materials is affected by many environmental factors, which mainly depends on the type of metal material and the type of environment. It is impossible to design a laboratory accelerated corrosion test room that includes all environmental factors that affect corrosion resistance. Therefore, the laboratory test is designed to simulate the factors that play a major role in the corrosion of metal materials. This equipment is designed to simulate and increase the impact of the environment on metal materials exposed to outdoor atmospheres with salt pollution and accelerated corrosion. The equipment includes test methods for cyclically exposing specimens to salt spray, dry, and humid heat environments. This equipment test is a comparative test, and the test results cannot predict the long-term results of the corrosion resistance of the same metal material used under these environmental conditions. However, this method can still provide valuable information on the relevant performance of materials exposed to salt pollution environments similar to the test conditions. Compared with traditional accelerated corrosion tests such as neutral salt spray test (NSS), acetic acid salt spray test (AASS), and copper accelerated acetic acid salt spray test (CASS), the biggest advantage of this equipment test is that it can better reproduce the corrosion occurring in outdoor salt pollution environments.

2. The accelerated corrosion test of this equipment is applicable to: metals and their alloys, metal coatings (anodic and cathodic), conversion coatings, anodized coatings, organic coatings on metal materials, etc.

Key Features:

The composite salt spray composite test room has the entire inner box space with corrosion resistance. The inner box is made of corrosion-resistant materials and has excellent thermal insulation performance. In addition, the equipment also has the following functions:

(1) It has an emergency braking function. A brake switch is installed on the equipment. When an abnormal situation occurs, the equipment can be powered off by controlling the switch.

(2) The equipment is equipped with corresponding system software. The software can run stably on the provided operating system. The software interface is in Chinese or English and has no service life limit. The software includes temperature change test, humidity, accuracy calibration part, and equipment self-test module part.

(3) The system software can record, automatically save, and optimize data in real time. The temperature-time, humidity-time and other curves can be drawn through software settings.

(4) The system software is equipped with a security protection parameter interface, and after the setting is completed, it will be given priority during the test process to ensure the safety of the test.

(5) The system software can achieve the function of test data security protection. The software has an administrator function that can limit the operating permissions of general operators.

(6) The system software has the function of post-data processing, and can support the import of multiple data files, data screening, and arbitrary X-axis and Y-axis selection.

(7) The equipment has multiple functions such as high temperature, wet heat, drying, and salt spray, and can realize automatic cycle control or single function control, simple operation, and data management.

Product Details:

 

Major Specifications:

Product name

Compound salt spray test chamber

Product model

CZ-15000D

Specimen restrictions This experimental equipment prohibits:

Testing or storage of flammable, explosive, volatile substance samples and corrosive substances

Testing or storage of biological samples

Testing or storage of strong electromagnetic emission source samples and testing and storage of radioactive material samples

Testing and storage of highly toxic substance samples or testing and storage of samples that may produce highly toxic substances during the storage process

Nominal volume About 15.6m³ including top sloping roof volume
Inner box size (mm) 2000×2300×3000 W×H×D (excluding sloping roof height)
Outer box size (mm) About 2300×3230×4350 WXH×D
Brine tank size (mm) Φ700×H 930
Net weight of equipment About 1550kg
Test environment conditions Ambient temperature is +25℃, relative humidity ≤85%RH, atmospheric pressure is 86~106Kpa, and there is no sample in the test chamber
Test room temperature range 20℃~+80℃
Saturated barrel temperature range RT+5℃~+80℃
Spray mode Continuous spray, intermittent spray, program spray three modes can be adjusted by yourself
Humidity range     777777777777777.png

Salt spray test cycle ≥ 95%RH, wet heat cycle 20%R.H~98%R.H (as shown)

Common alternating salt spray test conditions At 35℃ ambient temperature, 47℃ saturated barrel temperature, 5% salt water concentration spray test time 1min~999h can be set arbitrarily, then at 40℃±2℃ wet heat test temperature, 93%RH±2%RH, test time 1min~999h can be set arbitrarily; cycle 1~999 times can be set arbitrarily.

Then stand for 1min~999h under standard environmental conditions of temperature 23℃±2℃ and relative humidity 50%RH±5%RH, can be set arbitrarily.

Salt spray and drying alternating test At 35℃ ambient temperature, 47℃ saturated barrel temperature, 5% salt water concentration, spray test time 1min~999h can be set arbitrarily, then switch to 15~30℃ temperature, relative humidity less than 50%RH, drying test time 1min~999h can be set arbitrarily;
Other test conditions Can conduct NSS salt spray test, AASS acetic acid salt spray test, CASS copper accelerated acetic acid salt spray test, wet heat test, drying test, low temperature test, standard macroclimate environment test test conditions or other combined composite test conditions
Control accuracy Temperature resolution: 0.1℃

Humidity resolution: 0.1%R.H

Temperature deviation: ≤±2.0℃ Temperature uniformity ≤2℃

Humidity deviation: ≤+2-3%R.H when ≥75%RH; Humidity deviation: ≤±5%R.H when <75%RH;

Humidity uniformity: ≤+2-3%R.H when ≥75%RH; Humidity deviation: ≤±5%R.H when <75%RH

Temperature fluctuation: ±0.5℃

Humidity fluctuation: ±2%R.H

Note: Temperature uniformity and deviation are values ​​measured at an ambient temperature of +25℃, relative humidity ≤85%R.H, and without a sample.

Heating rate 20℃→80℃≤40min

Note: Heating time can be set. If the time is greater than 40 minutes, the equipment will heat up at a time rate. If the time is less than 40 minutes, the equipment heating control time rate setting is invalid

Cooling rate 80℃→20℃≤50min

Note: Heating time can be set. If the time is greater than 50 minutes, the equipment will heat up at a time rate. If the time is less than 50 minutes, the equipment heating control time rate setting is invalid

Salt spray deposition 1~3ml/h/80cm² (at least 16 hours of collection, take the average value)
Spray pressure 70~170Kpa
PH value 6.5~7.2
Meet the test method  

GB/T 31467.3-2015 Lithium-ion power battery pack and system for electric vehicles Part 3:

Safety requirements and test methods: salt spray test;

D0160 E/F/G salt spray test requirements GJB 150.11A-2009 Military equipment laboratory environmental test method salt spray test;

GB/T 2424.17-2008/IEC60068-2-11:1981 Salt spray test method;

GB/T 2423.18-2012/IEC 60068-2-52:1996 Sodium chloride alternating salt spray test method;

GB/T 2423.3-2006/IEC6008-2-78-2001 Test cab: Constant humidity test method;

GB/T 10125-2012/IS09227-2006 Artificial atmosphere corrosion test salt spray test; ASTM B117, ASTM B368

Equipment meets the test method GB/T5170.5-2008 Wet heat test equipment inspection method GB/T 10587-2006 Technical conditions for salt spray test chambers

GB/T 10586-2006 Technical conditions for damp heat test chambers

GB/T 5170.8-2008 Inspection methods for environmental test equipment for electrical and electronic products Salt spray test equipment

Noise Less than 75db (measured 1m from the front of the chamber and 1.2m from the ground)
Power supply AC(380±10)V (50±0.5)Hz three-phase four-wire + protective grounding

Frequently asked questions

How does my subscription work?

A seemingly elegant design can quickly begin to bloat with unexpected content or break under the weight of actual activity. Fake data can ensure a nice looking layout but it doesn’t reflect what a living, breathing application must endure. Real data does.

How do I edit what's in my plan?

Websites in professional use templating systems. Commercial publishing platforms and content management systems ensure that you can show different text, different data using the same template. When it’s about controlling hundreds of articles, product pages for web shops.

Can I change my next delivery date?

A seemingly elegant design can quickly begin to bloat with unexpected content or break under the weight of actual activity. Fake data can ensure a nice looking layout but it doesn’t reflect what a living, breathing application must endure. Real data does.

It's been a while since I took the quiz. Can I get a new recommendation?

Websites in professional use templating systems. Commercial publishing platforms and content management systems ensure that you can show different text, different data using the same template. When it’s about controlling hundreds of articles, product pages for web shops.

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Walk-in Composite Salt Spray Test Chamber 15m³”

Your email address will not be published. Required fields are marked *